Review





Similar Products

90
Nikon cfi plan apo objective lenses 60× air
Cfi Plan Apo Objective Lenses 60× Air, supplied by Nikon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/pm38971351-74-16-0
Average 90 stars, based on 1 article reviews
cfi plan apo objective lenses 60× air - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Thorlabs air doublet lenses (l1)
A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses <t>(L1)</t> is <t>used</t> <t>(AC254-030-B-ML</t> and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.
Air Doublet Lenses (L1), supplied by Thorlabs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/air+doublet+lenses++l1+/pmc10539404-234-4-13
Average 90 stars, based on 1 article reviews
air doublet lenses (l1) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
alcon inc monthly disposable silicone-hydrogel contact lenses air optixtm plus hydraglydetm
A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses <t>(L1)</t> is <t>used</t> <t>(AC254-030-B-ML</t> and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.
Monthly Disposable Silicone Hydrogel Contact Lenses Air Optixtm Plus Hydraglydetm, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/monthly+disposable+silicone+hydrogel+contact+lenses+air+optixtm+plus+hydraglydetm/pm37164776-52-1-9
Average 90 stars, based on 1 article reviews
monthly disposable silicone-hydrogel contact lenses air optixtm plus hydraglydetm - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Novartis air optix® contact lenses
A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses <t>(L1)</t> is <t>used</t> <t>(AC254-030-B-ML</t> and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.
Air Optix® Contact Lenses, supplied by Novartis, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/air+optix/us11648247-348-8-22
Average 90 stars, based on 1 article reviews
air optix® contact lenses - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Carl Zeiss plan neofluar na 0.3 air objective lenses
A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses <t>(L1)</t> is <t>used</t> <t>(AC254-030-B-ML</t> and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.
Plan Neofluar Na 0.3 Air Objective Lenses, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/40+air+objective+%C3%97/pm36779809-103-7-22
Average 90 stars, based on 1 article reviews
plan neofluar na 0.3 air objective lenses - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Thorlabs air-spaced achromatic lenses
A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses <t>(L1)</t> is <t>used</t> <t>(AC254-030-B-ML</t> and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.
Air Spaced Achromatic Lenses, supplied by Thorlabs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/achromatic+lens/pm36693241-181-9-9
Average 90 stars, based on 1 article reviews
air-spaced achromatic lenses - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
alcon inc air optix® lenses
A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses <t>(L1)</t> is <t>used</t> <t>(AC254-030-B-ML</t> and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.
Air Optix® Lenses, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/air+optix++lenses/us11520167-6-7-14
Average 90 stars, based on 1 article reviews
air optix® lenses - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
CIBA Vision sih lenses air-optix
A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses <t>(L1)</t> is <t>used</t> <t>(AC254-030-B-ML</t> and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.
Sih Lenses Air Optix, supplied by CIBA Vision, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/sih+lenses+air+optix/pmc04921210-26-19-23
Average 90 stars, based on 1 article reviews
sih lenses air-optix - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Nikon ni.1 brightfield compound upright microscope, 4 /10 /20 /air lenses
A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses <t>(L1)</t> is <t>used</t> <t>(AC254-030-B-ML</t> and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.
Ni.1 Brightfield Compound Upright Microscope, 4 /10 /20 /Air Lenses, supplied by Nikon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/pm35852018-54-20-11
Average 90 stars, based on 1 article reviews
ni.1 brightfield compound upright microscope, 4 /10 /20 /air lenses - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Nikon plan apochromat lamda 20x/0.75 numerical aperture air objective lenses
A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses <t>(L1)</t> is <t>used</t> <t>(AC254-030-B-ML</t> and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.
Plan Apochromat Lamda 20x/0.75 Numerical Aperture Air Objective Lenses, supplied by Nikon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/air+lenses/pm35103877-191-17-9
Average 90 stars, based on 1 article reviews
plan apochromat lamda 20x/0.75 numerical aperture air objective lenses - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses (L1) is used (AC254-030-B-ML and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.

Journal: Communications Biology

Article Title: Dynamic full-field optical coherence tomography module adapted to commercial microscopes allows longitudinal in vitro cell culture study

doi: 10.1038/s42003-023-05378-w

Figure Lengend Snippet: A mounted light-emitting diode (LED) (M810L3 or M730L5, Thorlabs, Newport, NJ, USA) with a wavelength of 810 nm and 25 nm bandwidth, or 730 nm and 40 nm bandwidth, is used as an extended source (S1) of 1 mm 2 with 61.8 μW mm −2 , or 13.1 μW mm −2 irradiance, respectively. A first pair of air doublet lenses (L1) is used (AC254-030-B-ML and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1). A pair of silver mirrors (M1 and M2) (PF10-03-P01, Thorlabs, Newport, NJ, USA) are used to steer the light into the microscope. An air doublet (L2) (AC254-100-B-ML, Thorlabs, Newport, NJ, USA) is used to image Ir1 onto the back focal plane of both objectives (Obj.1 and Obj.2) (UPLSAPO30XSIR, Olympus, Japan) by the intermediate of an air doublet (L3 and L4) (AC254-150-B-ML, Thorlabs, Newport, NJ, USA), respectively. A second iris (Ir2) is imaged onto the sample and M4, a silicon mirror (monocrystalline silicon wafer, Nanomaterials Development Experts Store, China) and is conjugated to a third iris (Ir3) by the intermediary of a non-polarizer-beam-splitter (NPBS), itself conjugated to a cMOS camera (Q-2HFW, Adimec, Netherland) by the intermediary of a pair of air doublet lens es(L5) (AC254-060-B-ML and AC254-200-B-ML, Thorlabs, Newport, NJ, USA). A steering mirror (M3) (PFE10-P01, Thorlabs, Newport, NJ, USA) and a manual translation stage (XY Trans) are used for alignment and fine positioning of Obj.2; standing vertically. A piezoelectric (PZT) (PK25LA2P2, Thorlabs, Newport, NJ, USA) and linear stage (Delay stage) (X-LSQ075A, Zaber, Canada) are used to introduce a fast or fixed phase shift between interferometric fields, respectively. A flat mirror (M5) (CCM1-P01/M, Thorlabs, Newport, NJ, USA) is mounted in the turret (IX3-RFACA-1–3, Rapp Optoelectronic, Germany) of a commercial microscope (IX83, Olympus, Japan). A commercial stage top incubator (H201-K-FRAME, H201-MW-HOLDER, and OBJ-COLLAR-2532, Okolab, Italy) enables temperature and humidity control, and CO 2 , O 2 , and N 2 gas composition whilst hosting conventional glass-bottomed multiwell plates. A 2-dimensional translation stage (SCANplus IM 120 × 80, 2 mm, Marzhauser, Germany) enables scanning from well to well, as well as mosaicking, and the objective holder of the microscope, mounted on a linear stage (U-MCZ-1-2, Olympus, Japan) enables depth (Z) scanning.

Article Snippet: A first pair of air doublet lenses (L1) is used (AC254-030-B-ML and AC254-150-B-ML, Thorlabs, Newport, NJ, USA) to image S1 onto a first diaphragm (Ir1).

Techniques: Microscopy, Introduce, Control